Cisco1941, Cisco1941W |
Services and Slot Density |
Embedded hardware-based crypto acceleration (IPSec) |
Yes |
Total Onboard LAN 10/100/1000 |
2 |
RJ-45-Based Ports |
2 |
SFP-Based Ports |
0 |
SM Slots |
0 |
Double-Wide SM Slots |
0 |
EHWIC Slots |
2 |
Double-Wide EHWIC slots (use of a double-wide EHWIC slot will consume two EHWIC slots) |
1 |
ISM Slots |
1 (0 on the Cisco 1941W) |
Memory (DDR2 Error Correction Code [ECC] ECC DRAM) - Default |
512 MB |
Memory (DDR2 ECC DRAM) - Maximum |
2.0 GB |
Compact Flash (external) - Default |
slot 0: 256 MB
slot 1: none |
Compact Flash (external) - Maximum |
slot 0: 4 GB
slot 1: 4 GB |
External USB flash memory slots (Type A) |
2 |
USB Console Port (Type B) (up to 115.2 kbps) |
1 |
Serial Console Port (up to 115.2 kbps) |
1 |
Serial Auxiliary Port (up to 115.2 kbps |
1 |
Power Supply Options |
AC, POE |
Redundant Power Supply Support |
No |
Power Specifications |
AC Input Voltage |
100-240 V ~ |
AC Input Frequency |
47-63 Hz |
AC Input Current range AC Power Supply (Max) (Amps) |
1.5-0.6 |
AC Input Surge Current |
<50 A |
Typical Power (No Modules) |
35 W |
Maximum Power capacity with AC power supply |
110 W |
Maximum Power capacity with PoE power supply (platform only) |
110 W |
Maximum PoE device power capacity with PoE power supply |
80 W |
Physical Specifications |
Dimensions (H x W x D) |
3.5 in x 13.5 in x 11.5 in |
Rack Height |
2 RU |
Rack-mount 19in. (48.3 cm) EIA |
Included |
Wall-mount (refer to installation guide for approved orientation) |
Yes |
Weight - with AC power supply (no modules) |
12 lbs |
Weight - with POE power supply (no modules) |
12.8 lbs |
Maximum Weight - Fully Configured |
14 lbs |
Airflow |
Front to Side |
Environmental Specifications |
Operating Condition |
Temperature - 5906 feet (1800 m) max. altitude |
0-40°C (32-104°F) |
Temperature - 9843 feet (3000 m) max. altitude |
0-25°C (32-77°F) |
Altitude |
3000 m (10000 ft) |
Humidity |
10 to 85% RH |
Acoustic: Sound Pressure (Typ/Max) |
26/46 dBA |
Acoustic: Sound Power (Typ/Max) |
36/55 dBA |
Transporation/Storage Condition |
Temperature |
-40-70°C (-40-158°F) |
Humidity |
5 to 95%RH |
Altitude |
4570m (15000 ft) |
Regulatory Compliance |
Safety |
UL 60950-1
CAN/CSA C22.2 No. 60950-1
EN 60950-1
AS/NZS 60950-1
IEC 60950-1 |
EMC |
47 CFR, Part 15
ICES-003 Class A
EN55022 Class A
CISPR22 Class A
AS/NZS 3548 Class A
VCCI V-3
CNS 13438
EN 300-386
EN 61000 (Immunity)
EN 55024, CISPR 24
EN50082-1 |
Telecom |
TIA/EIA/IS-968
CS-03
ANSI T1.101
ITU-T G.823, G.824
IEEE 802.3
RTTE Directive |